13. Glossary

Version 1.1Software: FuelTech VisionFirmware: 00.03.00.55Products: FT700, FT470, VisionFT2026-10-15

The terms used in the guide, in alphabetical order. Screen names appear in bold.

TermDefinition
Angular limitMaximum pulse duration in crankshaft degrees, counting the dead time. The smaller of it and the window width applies.
Anti-windupWith feed-forward on, the limit of the accumulator of the PID integral term: the maximum integral term is Ki × Anti-windup. Not used without feed-forward.
BankGroup of injectors (A, B or C). Each rail marks the banks it feeds.
Cam dependenceMakes the pump window follow the VVT deviation of the chosen cam. A retarded cam shifts the window later.
Camshaft degreeDegree measured on the cam, which turns at half the crankshaft speed. One camshaft degree equals 2 crankshaft degrees.
ClosingLobe #1 closing angle: end of the pulse, near the lobe peak, not at the peak. By sweep, the value ends up a few crankshaft degrees before it.
Commanded pulseDuration of the valve pulse, in ms, after all the ceilings. It is what is compared between maps.
ConsumptionAverage of the injection time, with dead time and corrections, of the marked banks. It is the basis of the feed-forward.
Control valvePump valve that the VCU turns on and off, once per lobe, to decide when the pump delivers. The VCU does not control the current.
Crank index positionAdjustment of the RPM signal: the tooth over the sensor with cylinder 1 at TDC. If wrong, all the pump angles come out shifted.
Crankshaft degreeDegree measured on the crankshaft: 720 per 4-stroke cycle, from the TDC of cylinder 1. The pump angles use this unit.
Dead timeSee dead time (t0).
Dead time (t0)Part of the pulse that does not deliver volume: t0 plus the curve by battery voltage. It only enters when there is demand.
Deceleration cutWith injector consumption below 0.3 ms and pressure 10 bar above the target, the VCU zeroes the pump pulse. Only with feed-forward.
DI1 and DI2Pressure sensor inputs of Rail #1 and Rail #2 (DI: direct injection). The channels DI Rail pressure #1 and DI Rail pressure #2 show the direct reading.
DutyCommanded pulse divided by the window width, in %. It is 100 in the start routine and 0 with the rail off.
Effective windowStart and end of the real pulse, in the channels GDI - Rail 1 window: effective opening and GDI - Rail 1 window: effective closing. The effective opening is the start of the pulse, not the typed angle.
Feed-forwardPhysical model that calculates the pulse from the injector consumption. With it on, the PID becomes just a correction, the trim.
Fill factorCurve by rpm (Fill factor (RPM)) that enters as a factor in the calculation of W, before the G(W) curve. With 1.00 there is no effect.
Filtered pressureReading of the rail sensor filtered at the stroke frequency, used by the loop. It is not in the log: filtered = target − error.
Flex IOFT470 pin that can be an output or an input. The pump pin stays as an output.
Full scaleThe highest pressure the VCU can see: the last point of the sensor table. Only a guard set below it acts (except Guard 2 through the condition target plus 20 bar, with the release below full scale), and a target above it is never seen as reached.
G(W)Capture curve: returns the crankshaft degrees of useful pulse needed to deliver the demand W.
GDIDirect injection (gasoline direct injection). The direct injection injectors are fed by the high pressure rail.
GuardPump overpressure protection: see Guard 1 and Guard 2.
Guard 1Pulse limiter: above the entry level, the pulse is limited to a % of the window width. It exits 3 bar below.
Guard 2Overpressure latch: turns off the rail pump and only releases below the release level. It does not cut the injectors.
High pressure fuel pump (HPFP)Mechanical pump driven by the cam lobes that takes fuel to the direct injection rail. The VCU controls only the pump control valve.
Injector lockoutAt start, the marked banks stay without a pulse until the minimum pressure, the Engine running RPM (disengages lockout) or the timeout. Requires feed-forward and the cut on.
KickShort boost added to the pulse when the injector consumption rises fast. It only adds, limited by the Kick upper limit.
Kp, Ki and KdProportional, integral and derivative gains of the PID. Kp and Ki are curves by rpm; Kd is a single value.
LatchLock that keeps Guard 2 active until the pressure drops below the release level or the VCU restarts. Stopping the engine does not release it.
Limp-homeSafe mode with the rail sensor declared failed. With feed-forward the pulse comes from the model only, without PID. Without feed-forward the pump turns off.
LobeCam bump that drives the pump. Each lobe gives one stroke per cycle.
LockoutSee injector lockout.
Low rail pressure injector cut-offInjectors of the marked banks stay without a pulse with the pressure below the limit and come back above the limit + 2 bar.
MAPManifold pressure. On the load axis of the target map it is in relative bar; vacuum is negative.
max ThetaShort name of the Angled window upper limit, used in the channel GDI - Angular upper limit (max Theta) rail 1.
OpeningLobe #1 opening angle: the earliest start the pulse can have. Together with the closing, it defines the window width.
Phase sensorSensor that confirms the phase of the 720 crankshaft degree cycle. The function requires it: without it half of the pulses fall outside the lobes.
Phase sweepField experience: at a fixed steady state, move opening and closing together (the width does not change), 10 crankshaft degrees per step up to ±20, and keep the step with the smallest pulse in ms.
PIDController that corrects the pulse by the pressure error, with the proportional, integral and derivative terms.
Pressure errorTarget minus the filtered pressure. Positive: the rail is below the target.
Pressurization (gain)Adds time to the pulse when the target rises and removes it when it falls, limited to ±1.5 ms.
Pump strokeEach pump delivery, one per lobe. The frequency is rpm × lobes ÷ 120 strokes per second.
RailThe fuel rail: the high pressure line that feeds the direct injection injectors. The function accepts 1 or 2 rails, each with an output and a sensor.
Rail offThe VCU stops commanding the rail valve: invalid width, no sync, no RPM, Guard 2 or, without feed-forward, sensor fault. In the log, the effective window stays at 0/0.
Start routineWith feed-forward, between 50 rpm and the Crank out RPM the valve is held on (duty 100), at most until the timeout.
SyncThe VCU recognizes the wheel and, with a phase sensor, confirms the phase. Before it the RPM is 0 and the valve is not driven.
TDCTop dead center. The pump angles count from the TDC of cylinder 1, like those of injection and ignition. It is not the lobe peak.
TrimPID correction with feed-forward on, in ms, between the floor (PID minimum trim or Trim floor: feedforward fraction) and the PID maximum trim.
VCUFuelTech control unit, FT700 or FT470, that controls the pump valve.
VVTVariable valve timing (Variable camshaft (VVT)). With Cam dependence, the pump window follows the cam offset.
W (demand)Consumption in ms corrected to 100 bar. Axis of the G(W) curve. The screen does not show the unit.
WindowRange of crankshaft degrees of lobe #1 between the opening and the closing. The width (closing − opening) is the pulse ceiling.
Window upper limitMaximum pulse duration that the window width allows: width ÷ (0.006 × rpm). The signal GDI - Lobe window upper limit rail 1 indicates when it limits the pulse.